Comparison of Coherence Measures for Assessment of Impaired Cerebral Autoregulation
D. De Smet*, S. Van Huffel*, J. Vanderhaegen**, G. Naulaers**
* Katholieke Universiteit Leuven, ESAT/SCD, Belgium
** University Hospitals Leuven, Neonatal Intensive Care Unit, Belgium
Submitted to the IEEE/EMBS Benelux Symposium, Heeze, The Netherlands, Dec. 2007.
Introduction
The statistical coherence method has been widely used to study the concordance between continuously measured signals intervening in the assessment of cerebral autoregulation in neonates. Several research groups [3,4,5] applied this method between mean arterial blood pressure (MABP) and cerebral signals (cerebral intravascular oxygenation -HbD- or cerebral tissue oxygenation -TOI-) acquired by near-infrared spectroscopy (NIRS). All groups brought a particular contribution to the fine-tuning of this method. We made a comparative study of all published results. This comparison is achieved by computing three previously defined parameters synthesizing the level of impaired autoregulation in a patient : the mean coherence [5], the pressure-passive index (PPI) [4], and the critical percentage of the recording time (CPRT) [2]. Finally, we looked at the concordance of these parameters with two developmental outcome parameters (post menstrual age -PMA- and body weight) by means of linear regression.
Methods
We compared coherence results obtained with the following parameters : the signals sample frequency, the duration of the successive (possibly overlapping) epochs into which the signals are divided prior to analysis, the values of the parameters intervening in the Welsh method (applied by all research groups), the frequency band of interest, and the critical coherence value from which impaired autoregulation is theoretically diagnosed. From the obtained coherence coefficients, we derived the mean coherence, the PPI, and the CPRT of the entire patient recording. These parameters allow us to presumably discriminate healthy from sick subjects. We finally compared both categories with the patients PMA and body weight.
Datasets
We included 20 premature infants at the NICU of the University Hospitals Leuven in need for intensive care. MABP, SaO2 (arterial oxygen saturation), HbD and TOI were measured simultaneously at the first days of life. The mean PMA was 28.7 weeks (24-39) and weight ranged from 570 to 1470g. HbD was calculated as the difference between oxygenated (HbO2) and deoxygenated hemoglobin (Hb). MABP was assessed by intravascular catheterization.
Results and Discussion
The coherence spectra differ if considering different values for the method parameters. The Welsh method remains a difficult method to optimize, as well as the determination of the most relevant frequency band. The PPI is better than just considering the mean coherence, and the CPRT is more sensitive than the PPI. All three synthesis parameters correlate with the considered developmental outcomes.
References
[1]
De Smet, D. et al. Detection of autoregulation in the brain of premature infants. Proc. of the IEEE/EMBS Annual Benelux Symposium and of Belgian Day on Biomedical Engineering, 215-218, 2006.
[2]
De Smet, D. et al. New measures for assessment of impaired cerebral autoregulation. Submitted to the Proc. of the 35th annual ISOTT meeting, 2007.
[3]
Morren, G. et al. Detection of autoregulation in the brain of premature infants using a novel subspace-based technique. Proc. of the 23rd Annual Intern. Conf. of the IEEE, 2, 2064-2067, 2001.
[4]
Soul, J. et al. Fluctuating pressure-passivity is common in the cerebral circulation of sick premature infants. Pediatric Research, 61(4), 467-473, 2007.
[5]
Wong, F. et al. Spatially resolved spectroscopy detects impaired cerebral autoregulation in very premature infants. Accepted by Pediatrics, to be published.