This file describes the data in exchanger.dat 1. Contributed by: Sergio Bittanti Politecnico di Milano Dipartimento di Elettronica e Informazione, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 MILANO (Italy) bittanti@elet.polimi.it 2. Process/Description: The process is a liquid-satured steam heat exchanger, where water is heated by pressurized saturated steam through a copper tube. The output variable is the outlet liquid temperature. The input variables are the liquid flow rate, the steam temperature, and the inlet liquid temperature. In this experiment the steam temperature and the inlet liquid temperature are kept constant to their nominal values. 3. Sampling time: 1 s 4. Number of samples: 4000 5. Inputs: q: liquid flow rate 6. Outputs: th: outlet liquid temperature 7. References: S. Bittanti and L. Piroddi, "Nonlinear identification and control of a heat exchanger: a neural network approach", Journal of the Franklin Institute, 1996. L. Piroddi, Neural Networks for Nonlinear Predictive Control. Ph.D. Thesis, Politecnico di Milano (in Italian), 1995. 8. Known properties/peculiarities: The heat exchanger process is a significant benchmark for nonlinear control design purposes, since it is characterized by a non minimum phase behaviour. In the references cited above the control problem of regulating the output temperature of the liquid-satured steam heat exchanger by acting on the liquid flow rate is addressed, and both direct and inverse identifications of the data are performed. Columns: Column 1: time-steps Column 2: input q Column 3: output th