This file describes the data generated by the mrs.m file 1. Contributed by: L. Vanhamme KUL, ESAT/SISTA Kard. Mercierlaan 94, 3001 Heverlee leentje.vanhamme@esat.kuleuven.ac.be 2. Process/Description: This simulation signal is derived from a typical in-vivo 31P spectrum measured in the human brain and consists of 11 exponentials. The 31P peaks from brain tissue, phosphomonoesters, inorganic phosphate, phosphodiesters, phosphocreatine, Gamma-ATP, Alpha-ATP and Beta-ATP are present in this simulation signal. 3. Sampling interval: The time sampling interval is 0.333 msec. 4. Number of samples the user can choose. Typical values however range from 256 to 1024. 5. Inputs: 6. Outputs: 7. References: L. Vanhamme, A. van den Boogaart, S. Van Huffel: Fast and accurate parameter estimation of noisy complex exponentials with use of prior knowledge , Proceedings EUSIPCO-96, Sept. 10-13 1996, Trieste, Italy. L. Vanhamme, A. van den Boogaart, S. Van Huffel: Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge , January 1997, submitted for publication in "Journal of Magnetic Resonance". (ESAT/SISTA report 97-02). 8. Known properties/peculiarities 9. Some MATLAB-code to retrieve the data The user can of course change the number of data point used to construct the data. He can als add noise with any desired standard deviation as described in the .m file.