1. Contributed by: Roy Smith Dept. of Electrical & Computer Engineering University of California, Santa Barbara, CA 93106 U.S.A. roy@ece.ucsb.edu 2. Process/Description: The experiment is a simple SISO heating system. The input drives a 300 Watt Halogen lamp, suspended several inches above a thin steel plate. The output is a thermocouple measurement taken from the back of the plate. 3. Sampling interval: 2.0 seconds 4. Number of samples 801 5. Inputs: u: input drive voltage ... 6. Outputs: y: temperature (deg. C) ... 7. References: The use of this experiment and data for robust control model validation is described in: "Sampled Data Model Validation: an Algorithm and Experimental Application," Geir Dullerud & Roy Smith, International Journal of Robust and Nonlinear Control, Vol. 6, No. 9/10, pp. 1065-1078, 1996. 8. Known properties/peculiarities The data (and nominal model) is the above paper have the output expressed in 10's deg. C. This has been rescaled to the original units of deg. C. in the DaISy data set. There is also a -1 volt offset in u in the data shown plotted in the original paper. This has been removed in the DaISy dataset. The data shows evidence of discrepancies. One of the issues studied in the above paper is the size of these discrepancies - measured in this case in terms of the norm of the smallest perturbation required to account for the difference between the nominal model and the data. The steady state input (prior to the start of the experiment) is u = 6.0 Volts.