Cerebral Tissue Oxygenation Can Be Used Instead of Cerebral Intravascular Oxygenation to Study Cerebral Autoregulation in Prematurely Born Infants (New Measures for Assessment of Impaired Cerebral Autoregulation)

D. De Smet*, J. Vanderhaegen**, G. Naulaers** and S. Van Huffel*
* SISTA, Dept. of Electrical Engineering, Katholieke Universiteit Leuven, Belgium
** Dept. of Paediatrics, University Hospital, Katholieke Universiteit Leuven, Belgium

Submitted to the 35th annual meeting of the International Society on Oxygen Transport in Tissue (ISOTT), Uppsala, Sweden, Aug. 2007. Accepted for oral presentation.
Full paper available at ftp://ftp.esat.kuleuven.be/sista/ddesmet/reports/0708-ISOTT.pdf


Background
Some preterm infants have poor cerebral autoregulation. The concordance between cerebral intravascular oxygenation (HbD) and mean arterial blood pressure (MABP) reflects impaired autoregulation. Unfortunately HbD isn't an absolute value. We've explored the relationship between HbD and the cerebral tissue oxygenation (TOI) to prove that TOI (absolute value) may replace HbD.

Methods
Several scores were computed to measure the concordance between MABP and HbD/TOI : correlation (COR), coherence (COH) and partial coherence (PCOH). From these, three mathematical tools were used to study the similarities between HbD and TOI : (1) a Correlation coefficient Between corresponding Score results (CBS); (2) a correlation coefficient related to the Percentage of the Recording Time during which each score is above half its maximal value (Critical PRT); (3) a regression line between both signal sets, computed from the mean per infant of each score.

Results
37 measurements in 20 preterm infants with a mean postmenstrual age of 28.7 weeks (24-39) and with need for intensive care were studied in the first days of life. HbD and TOI were obtained with the NIRO300 (Hamamatsu). Invasive MABP was measured continuously. The mean CBS is equal to 0.76 for COH, 0.63 for COR and 0.70 for PCOH. The correlation coefficient between CPRT curves is equal to 0.81 for COH, 0.71 for COR and 0.78 for PCOH. The regression's MSE is 0.0013 for COH, 0.0031 for COR and 0.0038 for PCOH.

Conclusion
HbD can be replaced by measurement of TOI for the calculation of cerebral autoregulation.