6.9 Parameter Sweep         

When you are not sure about good values for the ``Robustness'' and ``HF Gain'' parameters are, the ``Controller Parameter Sweep'' window of Figure 6.18 provides a solution. You start it from the menu entry Control $\rightarrow \;$Design Parameter Sweep. With this window you can sweep over a whole range of controllers (computed in batch). After the computation, a summary of all controllers is presented from which the ``optimal'' controller can be easily selected.


  
Figure 6.18: The ``Controller Parameter Sweep'' window shows the Tracking or Variance Objective for a whole range of ``Robustness'' and ``HF Gain'' values. You can easily select the optimal controller as the most right hand one. This figure show the Variance Objective ``Integral Absolute Error'' for a range of models.
\begin{figure}
\centering
\includegraphics [width=7.9cm]{line1.ps}
\end{figure}


Before you start the sweep, you have to enter the range of ``Robustness'' and ``HF Gain'' values in the top of the window. The title on top of the plot indicates how many controllers will be computed. After you entered the ranges, hit the ``Start'' button to initiate the computation of all controllers. The resulting window looks like Figure 6.18.

The plot shows on the x-axis a controller index and on the y-axis the Tracking or Variance Objective (Section 6.3.1). The controllers are ordered from left to right according to a decreasing objective. So, in theory, you should select the most right controller.

Just as for the identification sweep, care should be exercised, since the controller attaining the lowest object function could also be the one with the lowest ``Robustness'', or the highest ``HF Gain''. Move the mouse over the plot to display the parameters for the different bars in the top right corner of the window. In this way, you can select the controller with a small objective but with a reasonable robustness.

Once a good controller is selected, you export it to the main ``Control Design'' window, by hitting the export button. The ``Controller Parameter Sweep'' window is closed, and the signals related to the new controller are displayed in the main window. Re-opening the ``Controller Parameter Sweep'' window afterwards does not destroy the computed results. You can thus easily select a new controller and export it.



Peter Van Overschee
1/21/1998