Paper details
- TITLE: Measurement and analysis of feedback and nonlinearities for the Codacs direct acoustic cochlear implant
- AUTHORS: Giuliano Bernardi, Toon van Waterschoot, Marc Moonen, Jan Wouters, Martin Hillbratt, and Nicolas Verhaert
- ABSTRACT: Acoustic feedback is a very common problem in hearing instruments. Not only does it occur in common behind-the-ear (BTE) or in-the-ear hearing aids, it also affects bone-anchored hearing aids (BAHAs) and more recent devices, such as the direct acoustic cochlear implant (DACI).
For this reason, a feedback canceller module is a very important ingredient in hearing instruments design. A proper characterization of the feedback path can make the feedback-canceller design easier, given that this characterization can pro- vide a rough idea of the maximum gain the hearing instrument can supply without heading toward instabilities, e. g. howling, as well as helping in the decision of the most suitable feedback cancellation approach.
In this paper, we present the data and analysis relating to the feedback path char- acterization of the CochlearTM CodacsTM DACI, performed on fresh frozen cadaver heads in four different measurement sessions (MSs). The general objectives were the following: 1) To characterize the feedback path of the system and check for possible specimen-dependent variabilities; 2) To assess whether this feedback path is affected by an incorrect implantation; 3) To check for nonlinear behavior and 4) To determine differences between mechanical and airborne feedback.
The data analysis reveals that the feedback seems to be dependent on the specific head morphology of the implanted specimen, and that an incorrect implanta- tion might strongly affect the feedback path; additionally, the analysis reveals that some nonlinear behavior at high stimulus levels can be expected and, finally, that the feedback path is characterized by a mechanical feedback component with a rather different frequency content compared to the airborne (AB) feedback component.
- STATUS: ESAT-STADIUS Technical Report TR 15-181, KU Leuven, Belgium, submitted for publication, Aug. 2016.
- REPORT NUMBER: 15-181
Downloads
BibTeX entry
@Article{bernardi15-181,
author = {G. Bernardi and T. van Waterschoot and M. Moonen and J. Wouters and M. Hillbratt and N. Verhaert},
title = {Measurement and analysis of feedback and nonlinearities for the {Codacs} direct acoustic cochlear implant},
year = {ESAT-STADIUS Technical Report TR 15-181, KU Leuven, Belgium, submitted for publication, Jun. 2016.}
}
Related papers [Ear modeling]