-p223- Chapter 24: Awareness of Alarm Signals for Hard of Hearing, Deaf, and Deaf- Blind People Jos‚ Louis Delgado, Tord Israelson, Jan-Ingvar Lindstr”m, Jan H†vard Skjetne and Kevin Welsby Audible alarm signals are used for many purposes, from national emergencies to actions in daily living, such as door bells and baby alarms. They are ideally suited to hearing persons since they attract attention whatever else is being done. Hard of hearing and deaf people are excluded from receiving this important and potentially urgent information by their disability. However there are technical means by which this problem could be overcome. The solutions considered must take into account the needs of users in daily living, both at home and at work. Economic considerations and growing European integration suggest that systems should be common across Europe. This will ensure the lowest costs and be of great benefit to people travelling. Finally the systems proposed must also be adaptable to different national requirements, in particular for civil defense, and different applications where alarms are required for people with hearing disabilities. 1 User Needs Many alarm signals may be present in daily living or for special circumstances. It is practical to classify them into three groups: personal alarm signals, local area alarm signals and wide area alarm signals. 1.1 Personal Alarm Signals Personal alarm signals are for individual use. They may relate to immediate needs or may simply give information (alerting signals). Typical examples include: * Warning calls * Telephone bell * Door bell * Alarm clock * Timer * Machine needs attention The signals may be used at home or at work. In the case of warning calls and similar alarm signals, they may also occur in public places (e.g. airport terminals) or outdoors. The common factor is that the alarm signal, intended for either one or several specific users, is generated in the immediate area of the user and that the area of coverage required is small. 1.2 Local Area Alarm Signals Local area alarm signals relate to a generalised danger or warning, intended to reach many people. Examples include: * Fire/smoke alarms * Horns of approaching vehicles * Emergency vehicle sirens Alarms of this kind are widely used at work places, in hotels and in public places. In the case of vehicle alarms, these are generally intended to cover over a small area in the street. Again, a common factor is that these alarms are generated and used locally. 1.3 Wide Area Alarm Signals Wide area alarms are used by national authorities to indicate major incidents. These may relate to incidents at major industrial installations as well as natural disasters and hostile acts. The alarm signal is often given to the general population using high powered sirens, emitting an audible signal heard over a wide area. There are two important differences between wide area alarms on the one hand and personal and local alarms on the other. Firstly, the wide area alarm must be delivered over a large area. Secondly, the actions required by the person receiving the alarm will be unfamiliar and possibly complex. Further information will be needed, which can be derived from emergency plans and delivered by television, radio, teletext etc. In the case of hard of hearing and deaf users, special help may be needed through support services. 1.4 Response to Alarms For each of the alarms described above, the user will have to react in some way. It is essential to ensure that the alarm signal is reliably delivered to the hard-of-hearing and deaf users, and that the information given achieves the required reaction. There are three levels of response required to alarm signals. These are: * Alertness to a situation * Warning of danger - be ready * Immediate action required - e.g. get out and stay out Simple signalling with cadences can differentiate these alarm levels. However the user may have difficulty if more information is to be given, as in the case of wide area alarms. One possibility is that the user interface could include a text display. However this can only contain simple messages, for reasons of logistics. Pre-prepared short messages can convey enough information for a building to be cleared or an area avoided. The user must decide how to do this from the circumstances at the time. The information can only be provided at the time of danger and must be provided quickly and accurately if it is to be useful. The person providing the information cannot be expected to know the exact location and circumstances of the distant user. Hence we conclude that alarms cannot be specific to a user but can only inform people of the level of response required. Particular circumstances have to be dealt with by training (for example fire drills) and hard of hearing or deaf users may have to rely on the help of others for unknown situations. Finally, in the case of wide area alarms, a state of readiness must be assumed. These events can often be forecast and a great deal of information delivered to help in actions when the alarm occurs. A practical alarm system cannot be expected to deliver this information but must be supplemented with other information for the hard of hearing or deaf person. Suitable means include written and sign language through the medium of television, teletext, Radio Data System receivers etc. It is not likely to be practical to send messages to an individual in a given situation. 2 Technical Solutions Technical solutions are required for the user interface (personal alarm unit) and the alarm broadcast systems, for both wide and local area alarms. The concepts described above will of course need development and refinement. However many practical matters have been considered in reaching our conclusions. 2.1 Personal Alarm Unit The first consideration here is the user interface, i.e. how alarms are to be presented to the user. Hard of hearing or deaf people may have difficulty or be unable to hear the audible alarms often used, so that an alternative sensory input is required. An alarm signal must attract attention whatever the user is doing. Hence visual alarms such as text displays or even flashing lights can be ineffective since they may be out of the field of vision for much of the time. The user may even be asleep. Of the other senses the only practical possibility is a tactile signal. This could be provided by a body worn device. Topics for investigation would include: * Type of stimulation - electro or vibro-tactile stimulation * Place of stimulation - contact to the skin could either be at the back of a wrist-watch, or via a device in the pocket or elsewhere * Cadence, frequency and duration of stimulation to be given The personal alarm unit should be cordless. The signalling to the unit will be covered in the next section. The information to be carried will have to include the alarm signal itself as well as possible additional information. When alarm signals are sent, they are often intended for many people, i.e. applicable to all persons in the area. However there are many situations when the alarm will apply to one person only. For example an apartment block with many elderly and hard of hearing people may have several systems for signalling callers at the door. Some coding of this signal will be required to prevent false signals being given to personal alarm units. Hence alarm units should respond to at least two code signals, for individual and wide area alarms. 2.2 Local Area Alarms The issue of the cordless link to the personal alarm unit has been described separately since this needs careful integration of the requirements for local and civil defence alarms. Local area alarms are applicable over a variable area of coverage. They are required in daily living, in a house or work place, as well as in the street for emergency vehicle warnings. The special case of wide area alarms is covered in the section below. Desirable characteristics of the cordless transmission system are: * Coverage: The area of signal reception should be similar to that of audible alarms in general use. * User comfort: The receiver should be small enough to easily fit the pocket or ideally be wearable as a wristwatch. * Secure: The receiver should reliably operate within the required field of coverage when the user may be moving between rooms etc. * Personal: The receiver should not respond to signals addressed to other users in the vicinity for personal alerting signals. These could occur in the home, in the work place or in the park or playground. * General: The receiver should respond to local area alarms such as emergency vehicle and fire alarms or wide area alarms independent of personal warning. * Spectrum economy: Alarm signals will be relatively short and dispersed in area. The least possible bandwidth and number of frequencies should be specified for this service (users will be greatly assisted by a common system in use throughout at least Europe). * Ease of integration: Transmitters will need to be integrated with all alarm devices. This is more likely to happen if transmitters are cheap and easily connected to or integrated with existing audible alarms. 2.3 Wide Area Alarms Wide area alarms are required for those situations where large numbers of people, including the general population, must be warned in an area. This generally applies for civil defence purposes, although wide area alarms may also be used in large industrial installations. Many countries use acoustic sirens for civil defence alarms, especially in densely populated regions. However the sirens in the less densely populated regions do not give sufficient coverage to warn everyone. Alternative systems have been considered to ensure that these were capable of meeting the needs of hard of hearing and deaf people. Distribution through the electricity supply has limited scope. Since signals will not pass sub-stations or consumer motors, only limited areas can be covered. Similarly, distribution through the telephone network is limited by possible network congestion. The alternative is to use broadcast radio technology. Medium or long wave transmissions would cover an entire country. However the coverage is not well-controlled or defined for use in designating particular regions only. Paging technology has also been considered, but the function of this is to contact an individual regardless of location. It is not possible to send an alarm code to all users in a specific region. This is because a paging service operator will divide a country into zones on the basis of balancing traffic and tariffs. The zones may not relate to geographic areas and may not cover the entire country in the development of paging services. A technology which can meet the requirements for wide area alarms is the radio data system, RDS, standardised by EBU. The needs of people with disabilities have already been anticipated in RDS by the inclusion of the PTY31 code for alarms. Since RDS is delivered by local FM radio transmitters the system is well defined geographically for wide area alarms. Civil defence control stations have only to signal to the required transmitters to activate the PTY 31 code, which in turn activates the user's radio, at which time an alarm logo should be displayed. Consequently RDS and PTY31 are recommended as a wide area alarm system, especially for sparsely populated regions. However where acoustic sirens are used these may directly activate the personal alarm unit using a high power transmitter in place of the normal local transmitters used. This will extend civil defence warnings to all users of the personal alarm unit independent of any other systems. The system can easily be added to existing sirens. The merits of RDS versus the local alarm system has been discussed. However these systems are complementary. The user still requires a cordless link from the radio receiver to a personal alarm unit with tactile output. This can easily be integrated with the RDS receiver if an output is provided to signal the PTY31 code. A small local area transmitter will then activate the personal unit in the same way as the local alarm systems. Security is recognised as a main question to be considered, with special concern for the electrical power supply where power cuts may occur. Measures should be taken to ensure the following: * the personal alarm unit can be fed with power regularly (e.g. during the night); * the RDS receiver power supply should not be interrupted because of an electrical supply power cut of specified duration (e.g. less than 5 hours); * the entire civil defence alarm system should rely on a continuously recharged battery system (as in the case of telephone switches, for example). 3 Practical Implementation The previous sections have considered the awareness of alarms from a user's and a technical viewpoint. These issues will hopefully become clearer with the following description of how the system is intended to work. Note that this is a conceptual framework only, where many technical details will have to be resolved. The system is illustrated in Figure 25.1 Users will require a personal alarm unit. This will have a tactile (vibrator) output and may be worn in the pocket, or even on the wrist. The personal unit will warn of alarms at one of three levels differentiated by the cadence and frequency of the output. Ideally a small display will give additional information to confirm the type and source of the alarm. The personal alarm unit will receive signals from three sources: * Local alarms, assisting in daily living: These will indicate signals from telephone and door bells, babies crying, mother's warning etc. Also covered will be fire alarms etc, at work or at home or even in hotels throughout Europe. * A combined mode: Local alarm signals from transmitters used with civil defence sirens or emergency services vehicles. These will activate a general (not user specific) alarm. * Civil defence alarms through RDS: The RDS receiver will automatically activate the local alarm transmitter on receiving the PTY31 code. --------------------------------------------------------------------- Figure 24.1: Block diagram of the awareness system with wide and local area transmitter. The latter is connected with an interface, to which different alarm sources could be attached. --------------------------------------------------------------------- Hence hearing disabled people will have equal access to alarm and alerting signals. In daily life the use of the personal alarm unit will be of individual benefit. Also the system is constantly in use, so that users are regularly aware of alarm signals and the system is exercised to ensure its continued operation. In the street, the hearing disabled user can be made aware of emergency vehicles approaching and also civil defence sirens. At work and when travelling, hearing disabled people will be aware of fire alarms and also audible alarms used with machines. For civil defence, the inclusion of a relay with RDS receivers will allow these warnings to be relayed to the hearing disabled user even in the countryside (through the car or home radio). Establishing the system will require: * Marketing studies to determine user requirements across Europe, design issues and likely market size. * Technical studies into the technology of the personal alarm unit, local area transmitters, and the radio frequency to be used. Economical factors will be an important consideration, especially since large numbers of (simple low power) transmitters may be required. * Standards agreements to enable the production of compatible products. * The allocation of a radio frequency to be used in all areas for local area alarms. A defined allocation is required since the use of local area systems in hotels and large buildings and also in connection with sirens to cover a town, would otherwise interfere with services on the same frequency. * A strong recommendation for the implementation of a relay function with PTY31 on RDS receivers. Interfaces will be required for home, car, wrist- watch and pocket receivers to allow either direct operation of a vibrator or activation of the local area link to warn hearing impaired users. 4 Recommendations Conclusions of the presentation above, result in the following recommendations: * Technical studies should be initiated to define the local area system and especially the technology of the personal alarm unit for hard of hearing, deaf and deaf-blind people. * Marketing studies should be initiated to determine likely market size and user requirements of the alarm system. * Contact should be made with EBU to standardise a relay for RDS and PTY31, to activate a vibrator either directly or via the personal alarm unit. * Subsequently to the technical studies, proposals should be made to relevant international bodies to secure a standard radio frequency for use with alarm systems for disabled people. A world standard would be very convenient, the proposal should be made by a world deaf institution and an international or European civil defense body. * Consideration should be given at a political level to the proposals made, especially for the general use of alarm transmitters with audible and other alarms.