FILE: 00-102.ps.gz REPORT: 00-102 FORMAT: Compressed postscript AUTHORS: G. Morren, S. Van Huffel, I. Helon, G. Naulaers, H. Daniels, H. Devlieger and P. Casaer TITLE: The effects of non-nutritive sucking on heart rate, respiration and oxygenation: a model-based signal processing approach. ABSTRACT: Several studies support the idea that the use of pacifiers can reduce the risk of Sudden Infant Death Syndrome. To investigate the effect of non–nutritive sucking (NNS), we measured heart rate, abdominal respiration, EMG and arterial oxygen saturation of 20 neonates. In 10 of these neonates also changes in cerebral hemoglobin concentrations were acquired by means of near-infrared spectroscopy. Using a parametric technique to model the heart rate as a sum of exponentially damped sinusoids, two main frequency components were found in the heart rate during NNS: a frequency of about 0.08Hz, due to the alternation of sucking bursts and pauses, and a frequency of about 0.8Hz which reflects the influence of the respiration. Our analysis shows that it is the alternation of bursts and pauses itself that causes the increased heart rate variability, and that this is not due to increased effort. This suggests that the neuronal mechanism that regulates NNS also stimulates the heart rate. From our measurements, no effect of NNS on cerebral or peripheral oxygenation could be found. Furthermore, it has been shown that our model-based signal processing technique is well suited for the analysis of non-stationary biomedical signals. STATUS: Published in Comp. Biochem. Physiol. A 132(1) (May 2002) pp 97-106 ------------------------------------------------------------------------------ FILE: 01-52.ps.gz REPORT: 01-52 FORMAT: Compressed postscript AUTHORS: G. Morren, P. Lemmerling and S. Van Huffel TITLE: Decimative subspace-based parameter estimation techniques applied to magnetic resonance spectroscopy signals. ABSTRACT: In this paper, the problem of estimating the frequencies, dampings, amplitudes and phases of closely spaced complex damped exponentials in the presence of noise is considered. In several papers, decimation is proposed as a way to increase the performance of subspace-based parameter estimation methods, in the case of oversampling. In this paper, a novel extension of the HTLS-method that operates directly on the decimated data matrix is presented, and it is compared to other decimation methods. Experiments on simulated nuclear magnetic resonance (NMR) spectroscopy signals show the influence of decimation on the accuracy and computational complexity of the estimators. STATUS: Published in Proc. of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC2001), Istanbul, Turkey, October 25-28, 2001, CD-ROM, paper no. 850 (session 5.1.3) ------------------------------------------------------------------------------ FILE: 01-53.ps.gz REPORT: 01-53 FORMAT: Compressed postscript AUTHORS: G. Morren, P. Lemmerling, S. Van Huffel, G. Naulaers, H. Devlieger and P. Casaer TITLE: Detection of autoregulation in the brain of premature infants using a novel subspace-based technique. ABSTRACT: A recent study suggests that, under certain circumstances, concordant changes in cerebral intravascular oxygenation and mean arterial blood pressure reflect impaired cerebrovascular autoregulation. In this paper, we propose a new measure to quantitate this concordance, derived from the common subspace of these signals. The method is compared to correlation and coherence analysis with respect to our application, but it is also suited for other biomedical signals. Furthermore, this model-based approach is not restricted to applications involving only 2 signals. STATUS: Published in Proc. of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC2001), Istanbul, Turkey, October 25-28, 2001, CD-ROM, paper no. 1014 (session 4.5.1) ------------------------------------------------------------------------------ FILE: 01-129.ps.gz REPORT: 01-129 FORMAT: Compressed postscript AUTHORS: G. Morren, G. Naulaers, P. Lemmerling, S. Van Huffel, P. Casaer and H. Devlieger TITLE: Quantitation of the concordance between cerebral intravascular oxygenation and mean arterial blood pressure for the detection of impaired autoregulation. ABSTRACT: Since some important forms of brain injury in premature infants are caused in considerable part by disturbances in cerebral blood flow (CBF), it is important to be able to detect whether the cerebrovascular autoregulation, the mechanism by which CBF is maintained constant despite alterations in mean arterial blood pressure (MAP), is working properly. A recent study suggested that concordant changes in MAP and cerebral intravascular oxygenation (HbD), measured non-invasively by near-infrared spectroscopy (NIRS) as the difference between the concentration changes of oxygenated hemoglobin (HbO2) and deoxygenated hemoglobin (Hb), reflect impaired cerebrovascular autoregulation1. Consequently, premature infants with impaired cerebrovascular autoregulation could be identified by simultaneous, continuous measurements of HbD and MAP. From several premature babies, MAP, HbD and arterial oxygen saturation (SaO2) were measured simultaneously at the University Hospital Leuven, Belgium. The concordance between MAP and HbD was quantitated using three different measures, among which a newly developed measure that looks for similarity of the dynamics between signals. Some preliminary results obtained from the measured data are given. STATUS: Published in Proc. of ISOTT 2001, 29th Annual Meeting of the International Society on Oxygen Transport to Tissue, University of Pennsylvania - Philadelphia, USA, August 11-15, 2001 ------------------------------------------------------------------------------ FILE: 01-130.ps.gz REPORT: 01-130 FORMAT: Compressed postscript AUTHORS: G. Morren, M. Wolf, P. Lemmerling, U. Wolf, J. H. Choi, E. Gratton, L. De Lathauwer and S. Van Huffel TITLE: Extraction of fast neuronal changes from multichannel, functional near infrared spectroscopy signals using independent component analysis. ABSTRACT: Fast changes in the range of milliseconds in the optical properties of cerebral tissue, which are associated with brain activity, can be detected using non-invasive near-infrared spectroscopy (NIRS). These changes in light scattering are due to an alteration in the refractive index at neuronal membranes. The aim of this study was to develop highly sensitive data analysis algorithms to detect this fast signal, which is small compared to other physiological signals. A frequency-domain tissue oximeter, whose laser diodes were modulated at 110MHz was used. The amplitude, mean intensity and phase of the modulated optical signal was measured at 96Hz sample rate. The probe consisting of 4 crossed source detector pairs was placed above the motor cortex, contralateral to the hand performing a tapping exercise consisting of alternating rest- and tapping periods of 20s each. The tapping frequency, which was set to 3.55Hz or 2.5 times the heart rate of the subject to avoid the influence of harmonics on the signal, could not be observed in any of the individual signals measured by the detectors. An adaptive filter was used to remove the arterial pulsatility from the optical signals. Independent Component Analysis allowed to separate signal components in which the tapping frequency was clearly visible. STATUS: Proceedings of SPIE Vol. 4623, Progress in Biomedical Optics and Imaging Vol. 3 No. 15, p 68-76 (BiOS 2002, 19-25 January 2002, San Jose, California, USA) ------------------------------------------------------------------------------ REPORT: 02-12 FORMAT: Compressed postscript AUTHORS: G. Morren, P. Lemmerling and S. Van Huffel TITLE: Decimative subspace-based parameter estimation techniques. ABSTRACT: In this paper, the problem of estimating the frequencies, dampings, amplitudes and phases of closely spaced complex damped exponentials in the presence of noise is considered. In several papers, decimation is proposed as a way to increase the performance of subspace-based parameter estimation methods, in the case of oversampling . In this paper, three decimative versions of the HTLS-method, a subspace-based parameter estimation technique that operates directly on the data matrix, are derived and compared. Monte-Carlo simulation experiments show the influence of decimation on the statistical accuracy and the computational complexity of the algorithms. STATUS: Signal Processing, Vol. 83, No. 5, p. 1025-1033, May 2003 ------------------------------------------------------------------------------ REPORT: 02-184 FORMAT: Compressed postscript AUTHORS: G. Morren, P. Lemmerling, H. Daniels, G. Naulaers and S. Van Huffel TITLE: Sensitivity analysis of detrended fluctuation analysis applied to heart rate variability data. ABSTRACT: Detrended fluctuation analysis (DFA), a fractal analysis method which has been used frequently in heart rate variability (HRV) studies, is used to characterize the scaling behaviour of tachograms. Tachograms, the sequences of time intervals between successive heart beats, often contain specific types of nonstationarities. In the present paper, the effect of these nonstationarities on DFA is investigated. The following types of nonstationarities are considered: trends, discontinuities, spikes (missed R-peaks or decelerations), segments with different local standard deviations or correlations (corresponding to different sleep stages) and periodic components (respiratory sinus arrhythmia (RSA) or due to non-nutritive sucking (NNS)). Simulations using exact fractal signals with superimposed nonstationarities (as model for the tachograms), show how these nonstationarities affect the scaling behaviour of fractal signals. Based on the results of these simulations, guidelines are proposed which can be used to minimize the effect of the nonstationarities on DFA when applied to tachograms. STATUS: Submitted for publication in IEEE Transactions on Biomedical Engineering ------------------------------------------------------------------------------ FILE: 03-99.pdf REPORT: 03-99 FORMAT: PDF AUTHORS: G. Morren, M. Wolf, P. Lemmerling, U. Wolf, J. H. Choi, E. Gratton, L. De Lathauwer and S. Van Huffel TITLE: Detection of fast neuronal signals in the motor cortex from functional near infrared spectroscopy measurements using independent component analysis. ABSTRACT: Fast changes in the range of milliseconds in the optical properties of cerebral tissue, which are associated with brain activity, can be detected using non-invasive near-infrared spectroscopy (NIRS). These changes in light scattering are due to an alteration in the refractive index at neuronal membranes. The aim of this study was to develop highly sensitive data analysis algorithms to detect this fast signal, which is small compared to other physiological signals. A frequency-domain tissue oximeter, whose laser diodes were intensity modulated at 110MHz was used. The amplitude, mean intensity and phase of the modulated optical signal was measured at 96Hz sample rate. The probe consisting of 4 crossed source detector pairs was placed above the motor cortex, contralateral to the hand performing a tapping exercise consisting of alternating rest- and tapping periods of 20s each. The tapping frequency was approximately 2.5 times the heart rate of the subject in order to avoid the influence of harmonics on the signal. An adaptive filter was used to remove the arterial pulsatility from the optical signals. Independent component analysis allowed to separate a signal component in which the alteration of tapping- and rest-periods is visible in 10 out of 14 measurements. In those 10 measurements 71 out of 86 tapping periods were detected. STATUS: Submitted for publication in Medical and Biological Engineering and Computing