Subsections
You inspect the properties of the designed closed loops
(current, previous and benchmark) with the ``Closed Loop Properties'',
``Closed Loop Numerics'' and ``Closed Loop Analysis'' windows.
The ``Closed Loop Properties'' window displays the different properties
of the closed loop:
- Controller
-
Magnitude and phase of the current,
previous (dotted lines) and benchmark (dotted white lines) feedback
controller (CFB(z)). The design limit ``HF Gain'' is also
indicated in red (Figure 6.12).
- Open Loop
-
Magnitude and phase of the product of process and controller
transfer function (P(z) CFB(z)) of the current, previous
(dotted lines) and benchmark (dotted white lines) controller. The
dB line and 180 degrees lines are also plotted, so you can
readily read the phase and gain margins from the plot using data
viewing (Figure 6.15).
Figure 6.15:
The ``Closed Loop Properties'' window
showing the loop gain and phase of the current and previous
design. You can easily determine the gain and phase margins
through data viewing.
![\begin{figure}
\centering
\includegraphics [width=12.1cm]{line1.ps}
\end{figure}](img84.gif) |
- Nyquist Plot
-
Shows the Nyquist plot of the current, previous
(dotted) and benchmark (dotted white) controller. The Nyquist plot
is a plot of the product of process and feedback controller P(z)
CFB(z) in the complex plane. The design parabola (M-circle) is
also displayed in red (Figure 6.11).
- Closed Reference
-
The magnitude of the transfer
functions from reference to process output and process input. With
CFF (z) the feedforward part of the controller, the following
transfer functions are plotted:

- Closed Load
-
The magnitude of the transfer
functions from load to process output and process input. The
following transfer functions are plotted:

The second transfer function is what is classically called
the complementary sensitivity function.
- Closed Disturbance
-
The magnitude of the
transfer functions from disturbance to process output and process
input. The following transfer functions are plotted:

The first transfer function is what is classically called
the sensitivity function (Figure 6.16).
Figure 6.16:
The ``Closed Loop Properties'' window
showing the transfer functions from disturbance to process output
(sensitivity function) and to process input. The maximum of the
sensitivity function is also equal to the M-circle value.
![\begin{figure}
\centering
\includegraphics [width=12.1cm]{line1.ps}
\end{figure}](img84.gif) |
- Closed Poles
-
Shows the continuous poles of the
closed loop transfer function (the zeros of 1 + CFB(z) P(z)).
For more details on plotting poles and zeros, see
Section 5.6.1.
You can inspect some numerical values of the closed loop responses
with the ``Closed Loop Numerics'' window of Figure
6.17.
Figure 6.17:
The ``Closed Loop Numerics'' window
shows numerical values for closed loop properties for the current,
previous and benchmark design.
![\begin{figure}
\centering
\includegraphics [width=10.7cm]{line1.ps}
\end{figure}](img92.gif) |
- Gain Margin:
- The gain margin at the -180 degrees loop phase cross
over point.
- Gain Cross Over:
- The frequency where the loop gain reaches
dB.
- Phase Margin:
- The phase margin at the dB loop gain cross over
point.
- Phase Cross Over:
- The frequency where the loop phase reaches
-180 degrees.
- 3 dB Bandwidth:
- The frequency where the
transfer function from reference to process output is 3 dB lower
then its DC value.
- Step Rise Time:
- Rise time when applying a unit step to the reference input.
No anti-windup nor saturation effects of the process input are taken
into account (note that the design reference is not used
here, instead a unit step is applied).
- Step Settling Time:
- Settling time when applying a unit step to the
reference input. No anti-windup nor saturation effects of the
process input are taken into account (note that the design reference
is not used here, instead a unit step is applied).
- Step Overshoot:
- Overshoot when applying a unit step to the
reference input. No anti-windup nor saturation effects of the
process input are taken into account(note that the design reference
is not used here, instead a unit step is applied).
The ``Closed Loop Analysis'' window is very similar to the
``Signal Analysis'' window of the ``Data Acquisition'' window (Figure
4.5). You use it to inspect minimal, maximal and
mean values, standard deviations and energy levels in the different
signals. Section 4.6.1 contains more details.
Peter Van Overschee
1/21/1998