RaPID is equipped with two interfaces to the real world (file
transfer and real time operation) and with an interface to Simulink
(simulating the real world). These are also the three options
presented at startup of RaPID (after typing rapid at the Matlab
prompt).
- From File
-
When you start RaPID From File, all interaction with the
real world is through file transfer (Matlab or ASCII files). This
implies that the open loop data acquisition and the closed loop
validation have to be done off-line. You save the experimental data
into a transferable file and read it into RaPID. Figure
1.2 gives an overview of the different stages for
the From File mode.
Figure 1.2:
An overview of the four RaPID stages
when you start RaPID in the From File mode. All data
acquisition and interaction with the real world is done manually
through file transfer.
 |
- Simulink
-
Starting RaPID in Simulink mode, allows you to seamlessly
interact with a Simulink model. This model (which could be a very
complex, non-linear description of the reality) is used as a
simulator of the real world.
The open loop experiment is performed by simply (and
automatically) sending an input to the Simulink model. The output
is recorded and sent back to RaPID for further use. The same holds
for the closed loop validation stage, where the designed controller
and reference signal are automatically applied to the Simulink model
to assess the quality of the linear controller. This is illustrated
in Figure 1.3.
Figure 1.3:
An overview of the four RaPID stages
when you start RaPID in Simulink mode. All data acquisition and
simulation of the Simulink model is done automatically at the
click of a button.
 |
- Real Time
-
Finally, with RaPID started in Real Time mode, direct
interaction with the real world becomes possible. Starting and
stopping experiments means in this case sending and receiving data
directly from an industrial control device: an input-output board,
an industrial PID controller, a PLC or a DCS. All file transfer or
retyping of controller parameters is eliminated. For input-output
boards, the controller is guaranteed to run in real-time up to 40
kHz. Figure 1.4 illustrates the RaPID real-time
principle.
Figure 1.4:
An overview of the four RaPID stages
when you start RaPID in Real Time mode. All data acquisition and
down-loading of controllers is done through the real time
connection with the industrial control device. RaPID supports
input-output boards, industrial PID controllers, PLC's or DCS's.
 |
Peter Van Overschee