-p14- Modular Environmental Control and Communications System TIDE Project 112 Barry Redmond M'E'C'C'S' Consortium Introduction The MECCS project is funded by the Technology Initiative for the Disabled and Elderly (TIDE) programme of the European Community. The three partners in the consortium are the Central Remedial Clinic, Dublin, Ireland, the Technlogy Access Laboratory of the Dublin Institute of Technology, Dublin, Ireland, and Quest Enabling Designs Ltd, Fareham, UK. The project began in January 1992 and continues until March 1993. The project budget is 550 kECU with 64 man-months of effort. The objective of the project is to provide cost effective access to improved independence by designing a mobile system to give a user facilities for environmental control, communication and security. The device is intended to be mounted on a wheelchair, with a radio link to a fixed base unit. Essential features of the design are that it will have a modular system architecture, be adaptable to changing needs, and that it should be an immediately marketable product. The initial target user group for the system includes those with limited mobility, limited dexterity, or wheelchair users. The system will allow the user to monitor and control simple electrical devices such as lights, heaters, curtains and doors, It will provide full control of a television, and will provide monitoring, control and intercom facilities for the user's front door. It will allow the user to make and receive telephone calls. All these facilities will be available from the wheelchair as it moves about the home. Ideal System Architecture The ideal system would allow multiple mobile terminals for institutional or other environments where there are a number of users together. It would allow for multiple base units so that large buildings could be covered, and it would have a modular structure to allow for easy expansion of size or functions. However, for a number of reasons this ideal system is not practical at present and the design of the system requires a number of technical compromises in order to reach the objective of an immediately marketable product. These compromises are dealt with in the following sections. Radio Link The ideal system would have a single radio link for both voice and data but this is not practical at present. The radio technology must be available off the shelf now, it must be usable throughout Europe without a user licence, it must be low cost, and it must allow for future growth of the system functions. Since there is no technology filling all these requirements at present, the system will use two radio links, one for the data and one for the voice (telephone and intercom). The data radio link will use short range point-to-point public data channels and the voice radio link will use commercial cordless telephone technology. Digital European Cordless Telephone (DECT) technology appears to provide the integrated data and voice, and the pan-European licencing, but it is still not sufficiently widely available and is still too expensive. The consortium intend to design the system to move to DECT when it becomes practical. Mobile Terminal The design objectives for the mobile terminal, mounted on the wheelchair, are that it should provide a flexible user interface that can be easily adapted to varying user needs, that it should be low cost, and that it should allow for future system growth. In order to meet these objectives with minimum design effort the consortium have decided to use a laptop PC as the basis for the mobile terminal. The PC will communicate with the fixed base unit of the system via a mobile radio module connected to the serial port of the PC. Special user interface software will be written to run on the PC. Using a PC will have the added benefit that the user will be able to run other PC application software at the same time as the MECCS user interface. The user interface will be extremely simple to use and will take keyboard or switch inputs. The user interface software will be designed to run with Microsoft Windows in order to allow the user to switch between different applications while still having acces to the MECCS user interface. Almost every aspect of the operation of the user interface will be configurable by the user or installer, including selection of language for the screen messages. Control Bus Technology The MECCS system will control most devices in the user's environment using a bus system. In order to produce a marketable product within the short time of the project the system will use a commercially available bus system. The MECCS fixed base unit will be designed to have a bus adapter which will be changed to allow the system to be connected to any bus system, so that the bus system selected initially will not limit the choices available for future expansion of the MECCS system. In order to maximise the chances of commercial success the initial bus system must work over the existing powerline, to reduce the wiring required for installation, and it must be widely available now. The cost of the bus system components must be low, and it must require a minimum of design effort to interface it to the MECCS system. Although there are a number of sophisticated bus systems available or in development, the consortium have decided to use the American X10 system. There are a number of disadvantages to using X10. The most notable are that it is not possible to easily monitor the results of commands sent over X10, and it is not secure from operation by other X10 controllers nearby. However the consortium considered that these were outweighed by the availablity and particularly the very low cost of X10 components. The MECCS consortium have studied the Esprit Home Systems bus specification and consider that Home Systems could provide the most suitable solution to the bus requirements for the MECCS system. However, Home Systems is still only a specification and commercial devices are not expected to become available for a number of years. The MECCS consortium intend that the MECCS system will use the Home Systems bus when it becomes available at sufficiently low cost. In preparation for this, the MECCS system has been designed to use the same subset of the OSI 7 layer reference model for communications as is used by Home Systems, and the MECCS system uses internally a subset of the Home Systems command language. This is expected to ease the eventual move to Home Systems. Core System The ideal MECCS system is based very much on commercially available components and is strongly modularised, but it is still missing some of the functions which were project objectives. There is no telephone, no door intercom, and no television control. The telephone and intercom are missing because the radio link is a simple data link which is not capable of carrying voice. Television control is missing because the X10 bus is not capable of providing the level of control required to change variables such as channel and volume. Full System In order to add the functions missing as a result of the technical design compromises, it is necessary to add special modules and links to provide these functions. The telephone and intercom functions will be provided by adding a commercial cordless telephone. The handset will be mounted on the wheelchair and connected to the mobile terminal so that it can be controlled from the user interface on the PC. The base unit of the cordless telephone will be connected to the telephone line as normal, and also to the door intercom. Therefore there will be two radio links with the mobile terminal on the wheelchair, one for data and one for voice. To provide control of a television, the system will include a commercial infra-red remote control unit mounted on the wheelchair. The IR controller will be connected to the mobile terminal equipment and will be controlled from the user interface on the PC. The door monitor and control functions will be connected directly to the fixed base unit rather than depending on the X10 bus. This is to ensure that the functions will be available even when the mains power has failed. Future Improvements There are a number of possible improvements to the MECCS system. The use of the X10 bus system limits the functionality of the system to simple on/off commands. The move to the Home Systems bus, when it becomes available, will add greatly to the usefullness of the system. It will allow the user to monitor the actual state of controlled devices, and it will allow the control of a much wider range of devices, including the television, over the bus. It will also allow the MECCS system to be more integrated with other systems in the house. The change to DECT for the radio link will bring a range of communications facilities to the system. It will simplify the system operation and allow it access to the expanding range of digital services available via the telephone. It will improve the quality of voice and data links to the wheelchair. DECT will also provide a European-wide and probably world-wide standard so that a single version of the MECCS radio hardware can be sold in all countries. Other future enhancements will be in the area of user input and output options. Because the system is based on a PC it will be possible to add such facilities as voice input and output and enlarged text display. The MECCS system will become more intgrated with communication aids and with the operation of the wheelchair itself. The design and packaging of the MECCS system will improve so that it will become more usable in a variety of situations. Conclusion The MECCS system will provide an integrated but modular system to provide mobile environmental control and communication functions for wheelchair users. The design is very commercially motivated and is intended to be brought to market after the TIDE funded development project is completed. The functions to be provided by the system have been carefully selected to give a usable but affordable system based on available technology.